The LTV6 and LTV8 light towers combine the features and performance of traditional light towers in a small footprint. They are ideally suited for illuminating general job sites, site prep, concrete pours, specialty events, parking lots, road work and bridge work. The adjustable vertical mast extends 23 feet and can rotate 360 degrees for optimum lighting flexibility.
LTV6L | LTV6K | LTV6K LED | ||
---|---|---|---|---|
Operating data |
||||
L x W x H in | 101 x 58 x 99 | 101 x 58 x 99 | 101 x 58 x 99 | |
Operating weight lb | 1,760 | 1,790 | 1,790 | |
Shipping weight lb | 1,430 | 1,460 | 1,460 | |
Illumination coverage at 5 fc (54 lux) ft² | 12,918 | 12,918 | 5,396 | |
Lamp type | Metal Halide | Metal Halide | LED | |
Mast height ft | 23 | 23 | 23 | |
Sound level (LwA) at 23 ft (7 m)dB(A) | 67.9 | 68.3 | 68.3 | |
Power kW | 6 | 6 | 6 | |
Frequency Hz | 60 | 60 | 60 | |
Voltage V | 120 | 120/240 | 120/240 | |
Power factor cos Φ 1~ | 1 | 1 | 1 | |
Engine / Motor |
||||
Generator model | Brushless | Brushless | Brushless | |
Generator insulation (class) | H | H | H | |
Idle to full load % | 10 | 10 | 10 | |
Voltage control (+/-) % | 6 | 6 | 6 | |
Engine / Motor manufacturer | Kohler (LDW1003) | Kubota (D1005) | Kubota (D1105) | |
Engine / Motor type | Liquid-cooled 3-cylinder | Liquid-cooled 3-cylinder | Liquid-cooled 3-cylinder | |
Fuel type | Diesel | Diesel | Diesel | |
Displacement in³ | 62.7 | 61.1 | 68.5 | |
Operating performance hp | 12.2 | 13.1 | 15.4 | |
at rpm rpm | 1,800 | 1,800 | 1,800 | |
Rated performance | ISO 3046 IFN | ISO 3046 IFN | ISO 3046 IFN | |
Tank capacity (Oil) US qt | 4 | 5.4 | 5.4 | |
Tank capacity (Fuel) US gal | 45.8 | 45.8 | 45.8 | |
Fuel consumption (Prime Load)US gal/h | 0.72 | 0.68 | 0.68 | |
Runtime 100% Prime Load h | 60.5 | 64.3 | 64.3 | |
Runtime 4 Lights Only h | 98.8 | 104.3 | 136.9 |